Opleiding: Certified TIA-942 Design Consultant - CTDC® (exam incl.) (English)

Lesmethode :

Klassikaal

Algemeen :

Data centres are at the core of many organisations. Downtime of the data centre could lead to major losses to the business. This has led many organisations to build resilience at various levels, such as at the data centre facilities, infrastructure and at the ICT layer. However, following recommendations of various vendors, consultants and public domain information might result in under- or over-specification. Therefore it would be better to follow a commonly accepted standard as the basis for the design and build principles.

The ANSI/TIA-942 Standard specifies requirements and guidelines for the design and build of a data centre. It is intended for use by designers who need a comprehensive understanding of the data centre design encompassing Architecture, Mechanical, Electrical and Telecom requirements and guidelines, not always covered by other generic guidelines and so called "standards". Understanding the intent of the ANSI/TIA-942 standard is of fundamental importance, not only for the successful implementation of the data centre, but also for its sustainable operations.

In this three-day course, the participant will learn how to design an ANSI/TIA-942 compliant data centre. It will provide a clear understanding of the requirements of the ANSI/TIA-942 Standard and possible implementation variations. The course is well suited for all types of data centres, be it enterprise data centres or multi-tenant, third party data centres such as co-location, managed services and cloud service providers.

Certification

After completing the course, you will be prepared for the internationally recognised EPI exam. The certificate is valid for three years.

Exam at the training location

As standard, you will take the exam at the training location on the final course day. The exam is delivered digitally via EXIN Online. You must bring your own laptop with a working browser and internet connection. The trainer will act as the exam supervisor.

Online exam at a later time

If you attend the course online via Microsoft Teams, are unable to be physically present on the final course day, or there is insufficient time to take the exam during the course, you will receive an EXIN Anywhere voucher. This allows you to take the exam online at a time of your choice.

Doel :

Comprehend and apply the ANSI/TIA-942 Standard requirements and guidelines
Understand the proper intent of the Standard to avoid both over- and/or under investment
Align Tier level selection and infrastructure investments to the business requirements
Understand the criteria and requirements for a high availability data centre design and how to effectively
establish the data centre from the perspective of the Standard
Understand how the ANSI/TIA-942 standard relates to various worldwide standards

Doelgroep :

Professionals in design, build, maintenance and operation of mission critical datacentres and those who wish to attend the CTIA (Certified ANSI/TIA-942 Internal Auditor) course.

Voorkennis :

Participants need to possess a valid data center certification, such as CDCP or equivalent. It is also mandatory to hold a copy of the latest version of the ANSI/TIA-942 standard. Vijfhart will order this copy for you. In order to do this, the participant will have to send Vijfhart a digital copy of their valid datacenter certification.

Approximately 10 working days before the start of the training, Vijfhart will send a request to order the copies of the ANSI/TIA-942 standard. Students will receive an email with a link to their copy. It is highly recommended to study the standard before the start of the training because the training aims to teach the student how to use and interpret the standard. In the exam you can expect questions about or related to facts in the standard. The printed copy of the standard is needed at the start of the training.
En de volgende cursussen:

  • Certified Data Center Professional - CDCP® (incl. examen)

Onderwerpen :


- Introduction to Data Centre facilities
- About the ANSI/TIA-942
+nbsp;+nbsp;+nbsp;- Life of the ANSI/TIA-942 Standard
+nbsp;+nbsp;+nbsp;- Relation to other standards
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Architectural
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Electrical
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Mechanical
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Telecommunication
+nbsp;+nbsp;+nbsp;- Areas under scope
+nbsp;+nbsp;+nbsp;- High level Tier definitions
+nbsp;+nbsp;+nbsp;- Redundancy options (N, N+1 etc.)
+nbsp;+nbsp;+nbsp;- Fault tolerant
+nbsp;+nbsp;+nbsp;- Concurrent maintainability
+nbsp;+nbsp;+nbsp;- Compartmentalization
+nbsp;+nbsp;+nbsp;- Examples of redundancy levels
- Data Centre Space Planning
- Data Centre Topologies
- Recommendations for Energy Efficiency
- Architectural
+nbsp;+nbsp;+nbsp;- Site selection
+nbsp;+nbsp;+nbsp;- Parking
+nbsp;+nbsp;+nbsp;- Multi-tenant building
+nbsp;+nbsp;+nbsp;- Building construction
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Vapor barrier
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Roofing
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Floor loading
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Raised flooring
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Suspended/drop ceiling
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Hanging load
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Seismic
- Building Security & Safety
- Security
- CCTV
- Sta ffing
+nbsp;+nbsp;+nbsp;- Bullet/ballistic profo ng
+nbsp;+nbsp;+nbsp;- Lighting
+nbsp;+nbsp;+nbsp;- Safety
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Signage
- Building and Room Access
+nbsp;+nbsp;+nbsp;- Security checkpoints
+nbsp;+nbsp;+nbsp;- Entry lobby
+nbsp;+nbsp;+nbsp;- Doorsand windows
+nbsp;+nbsp;+nbsp;- Exit corridors
+nbsp;+nbsp;+nbsp;- Shipping and receiving areas
- Room/Area Design Requirements
+nbsp;+nbsp;+nbsp;- Administrative off ces
+nbsp;+nbsp;+nbsp;- Security offi ce
+nbsp;+nbsp;+nbsp;- Operations centre
+nbsp;+nbsp;+nbsp;- Restroom and break room
+nbsp;+nbsp;+nbsp;- UPS/Battery rooms
+nbsp;+nbsp;+nbsp;- Generator and fuel storage area
+nbsp;+nbsp;+nbsp;- Computer room
- Electrical
+nbsp;+nbsp;+nbsp;- Utility power
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Substation
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Feed requirements
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Self-generation
+nbsp;+nbsp;+nbsp;- HT/HV switch gear
+nbsp;+nbsp;+nbsp;- Generator and fuel supply
+nbsp;+nbsp;+nbsp;- LT/LV switch gear
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- ATS
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Alternatives to ATS
+nbsp;+nbsp;+nbsp;- UPS and batteries
+nbsp;+nbsp;+nbsp;- PDU
+nbsp;+nbsp;+nbsp;- STS
+nbsp;+nbsp;+nbsp;- Grounding
+nbsp;+nbsp;+nbsp;- Surge protection
+nbsp;+nbsp;+nbsp;- EPO
+nbsp;+nbsp;+nbsp;- Central power monitoring
+nbsp;+nbsp;+nbsp;- Load Banks
+nbsp;+nbsp;+nbsp;- Testing
+nbsp;+nbsp;+nbsp;- Equipment maintenance
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Preventive maintenance
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Facility training programs
- Mechanical
+nbsp;+nbsp;+nbsp;- Environmental design
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Temperature and humidity requirements as per ASHRAE TC9.9
+nbsp;+nbsp;+nbsp;- Contamination
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Sources
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Clean Air
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Pressurization
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Radio Sources
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Vibration
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Water ingress
+nbsp;+nbsp;+nbsp;- Water cooled systems
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Heat rejection
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Chilled water system
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Condenser water
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Make up water
+nbsp;+nbsp;+nbsp;- Air cooled systems
+nbsp;+nbsp;+nbsp;- HVAC control systems
+nbsp;+nbsp;+nbsp;- Plumbing
+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;+nbsp;- Pipe routing
+nbsp;+nbsp;+nbsp;- Fire suppression
+nbsp;+nbsp;+nbsp;- Water leak detection
- Telecommunications
+nbsp;+nbsp;+nbsp;- Network topology
+nbsp;+nbsp;+nbsp;- Redundancy level design
+nbsp;+nbsp;+nbsp;- Media and connectors
+nbsp;+nbsp;+nbsp;- Cabling pathways
+nbsp;+nbsp;+nbsp;- Detailed cabling design considerations
+nbsp;+nbsp;+nbsp;- Administration and labeling
+nbsp;+nbsp;+nbsp;- Cable testing
+nbsp;+nbsp;+nbsp;- Data centre fabrics
- Exam
+nbsp;+nbsp;+nbsp;- Exam: Certified TIA-942 Design Consultant

Meer...
€3.225
ex. BTW
Aangeboden door
Vijfhart opleidingen
Onderwerp
Consultancy
Niveau
Duur
3 dagen
Looptijd
3 dagen
Taal
en
Type product
cursus
Lesvorm
Examen
Aantal deelnemers
Min: 4
Max: 12
Tijdstip
Overdag
Keurmerken aanbieder
Cedeo
VOI
Oracle Education Partner
AgilePM - Agile Project Management (APMG)
EXIN
Microsoft Learning Partner
Erkend keurmerk
CRKBO en BTW-vrijstelling
CRKBO zonder BTW vrijstelling
IPMA