Opleiding: Certified Network Cabling Design Professional (CNCDP®) (exam incl.) (English) (Virtual)
Lesmethode :
Virtueel
Algemeen :
With few exceptions, enterprises today rely on IT for the delivery of business-critical services - often directly to the end consumer. It is therefore vital that the mission-critical data centre is designed, maintained and operated with high-availability and efficiency in mind. Among all the facilities, network cabling is the foundation for the network and one of the major contributors to the availability of the data center.
CNCDP® is a 2-day course designed to expose participants to in-depth knowledge in designing and installing the data network cabling system which includes key subject matters such as; technical standards, designing of different cabling sub-systems, calculation of material requirements, architecture, installation, testing and acceptance.
Certification
After completing the course, you will be prepared for the internationally recognised EPI exam. The certificate is valid for three years.
Exam at the training location
As standard, you will take the exam at the training location on the final course day. The exam is delivered digitally via EXIN Online. You must bring your own laptop with a working browser and internet connection. The trainer will act as the exam supervisor.
Online exam at a later time
If you attend the course online via Microsoft Teams, are unable to be physically present on the final course day, or there is insufficient time to take the exam during the course, you will receive an EXIN Anywhere voucher. This allows you to take the exam online at a time of your choice.
Doel :
After completing the course, you can design and validate structured network cabling and patching systems for commercial buildings and data centres by applying standards, selecting the right pathways, and using correct installation and testing practices for copper and fibre.
Doelgroep :
This course is intended for IT, facilities, and data centre professionals, consultants, and anyone involved in network cabling system design, implementation, or operations.
Voorkennis :
There is no specific prerequisite for the CNCDP® course. However, participants who already have at least one or two years experience in a IT, data centre or facilities environment may be best suited. Those with no experience just yet are most welcome to participate.
Onderwerpen :
- Introduction to Structured Cabling System (SCS)
+nbsp;+nbsp;+nbsp;- Brief history of SCS
+nbsp;+nbsp;+nbsp;- Basic copper and fibre transmission
+nbsp;+nbsp;+nbsp;- Copper and fibre cabling
+nbsp;+nbsp;+nbsp;- Single and multimode fibre
+nbsp;+nbsp;+nbsp;- Step/graded index multimode fibre
+nbsp;+nbsp;+nbsp;- Difference between Commercial Wiring and data centre cabling
+nbsp;+nbsp;+nbsp;- Development of standards
+nbsp;+nbsp;+nbsp;- Role of standards
+nbsp;+nbsp;+nbsp;- ANSI/TIA 568 standard
+nbsp;+nbsp;+nbsp;- Common standards
+nbsp;+nbsp;+nbsp;- The new usage of cabling to support Smart building
- Horizontal and Administration - Commercial Building
+nbsp;+nbsp;+nbsp;- Standard diagram recap: ANSI/TIA-568
+nbsp;+nbsp;+nbsp;- Functional elements and example
+nbsp;+nbsp;+nbsp;- Scenario A: Determine the number of work areas
+nbsp;+nbsp;+nbsp;- Scenario B: Determine the number of user locations
+nbsp;+nbsp;+nbsp;- Zone wiring
+nbsp;+nbsp;+nbsp;- Administration: Interconnect and cross-connect
+nbsp;+nbsp;+nbsp;- Angled and flat panels
+nbsp;+nbsp;+nbsp;- Creating a cabling schematic design
+nbsp;+nbsp;+nbsp;- Convert schematic into physical layout
+nbsp;+nbsp;+nbsp;- Calculating the material list
- Horizontal and Administration - Data Centre
+nbsp;+nbsp;+nbsp;- Standard diagram recap: TIA-942
+nbsp;+nbsp;+nbsp;- Basic/Reduced/Typical data centre setup
+nbsp;+nbsp;+nbsp;- Traditional 3 layers network design/ Spine and Leaf network design
+nbsp;+nbsp;+nbsp;- Select termination hardware
+nbsp;+nbsp;+nbsp;- Administration design
+nbsp;+nbsp;+nbsp;- ToR/EoR/Spine & Leaf cabling design
+nbsp;+nbsp;+nbsp;- Network and cabling resiliency
+nbsp;+nbsp;+nbsp;- Create cabling schematic design for ToR/EoR
+nbsp;+nbsp;+nbsp;- Convert into patch panel/rack layout
+nbsp;+nbsp;+nbsp;- Calculate the material list for ToR/EoR
- Building Backbone - Commercial Building
+nbsp;+nbsp;+nbsp;- Backbone diagram
+nbsp;+nbsp;+nbsp;- Calculate the copper backbone requirements per Telecom Room (TR)
+nbsp;+nbsp;+nbsp;- Calculate the fibre backbone requirements per Telecom Room
+nbsp;+nbsp;+nbsp;- Summarize the building backbone requirements
+nbsp;+nbsp;+nbsp;- Recognised cables
+nbsp;+nbsp;+nbsp;- Backbone Patch panels
+nbsp;+nbsp;+nbsp;- The maximum backbone distances
+nbsp;+nbsp;+nbsp;- Create cabling schematic design
+nbsp;+nbsp;+nbsp;- Converting the schematic design into patch panel/ rack layout
- Building Backbone - Data Centre
+nbsp;+nbsp;+nbsp;- TIA-942 based backbone topology
+nbsp;+nbsp;+nbsp;- TIA-942 backbone requirements
+nbsp;+nbsp;+nbsp;- Recognised backbone cable
+nbsp;+nbsp;+nbsp;- ToR/EoR/Spine and Leaf
+nbsp;+nbsp;+nbsp;- Backbone distance estimation
+nbsp;+nbsp;+nbsp;- Resiliency of backbone cable routes
+nbsp;+nbsp;+nbsp;- Creating cabling schematic design
+nbsp;+nbsp;+nbsp;- Converting the schematic design into patch panel/ rack layout
+nbsp;+nbsp;+nbsp;- Field and Fusion Termination for fibre connectors
+nbsp;+nbsp;+nbsp;- Pre-terminated fibre trunk and copper cables
- Architectural Considerations
+nbsp;+nbsp;+nbsp;- ANSI/TIA569-D Cable pathway and spaces
+nbsp;+nbsp;+nbsp;- Common requirements for the rooms
+nbsp;+nbsp;+nbsp;- Definition of the rooms
+nbsp;+nbsp;+nbsp;- Entrance Room/Demarcation
+nbsp;+nbsp;+nbsp;- Ceiling and floor pathways types
+nbsp;+nbsp;+nbsp;- Cable trays/basket/ladder/conduit
+nbsp;+nbsp;+nbsp;- Inner duct/sleeve/slot
+nbsp;+nbsp;+nbsp;- Calculating of pathway size
+nbsp;+nbsp;+nbsp;- Cable run best practices
+nbsp;+nbsp;+nbsp;- Cable management/AIM
+nbsp;+nbsp;+nbsp;- Grounding and bonding
+nbsp;+nbsp;+nbsp;- Separation distance requirements for copper cabling to power cabling
+nbsp;+nbsp;+nbsp;- Fire stopping
+nbsp;+nbsp;+nbsp;- Fire rated barrier
+nbsp;+nbsp;+nbsp;- Fire rated jacket cable
- Campus / Outdoor Backbone
+nbsp;+nbsp;+nbsp;- Common campus cable installation and cable types : Aerial cable / Direct-buried / Underground in-conduit
+nbsp;+nbsp;+nbsp;- Outdoor cable installation planning
+nbsp;+nbsp;+nbsp;- Lightning / surge protection
+nbsp;+nbsp;+nbsp;- Approved ground for surge protector
+nbsp;+nbsp;+nbsp;- Creating a schematic diagram
+nbsp;+nbsp;+nbsp;- Converting a schematic into a physical layout
- Site Inspection and Testing
+nbsp;+nbsp;+nbsp;- Visual site inspection notes
+nbsp;+nbsp;+nbsp;- Installation common issues
+nbsp;+nbsp;+nbsp;- Copper testing standard
+nbsp;+nbsp;+nbsp;- Permanent link / Channel / Patch cord / MPTL testing configuration
+nbsp;+nbsp;+nbsp;- Fibre connectors
+nbsp;+nbsp;+nbsp;- Fibre testing standard
+nbsp;+nbsp;+nbsp;- Tier 1 & 2 certification
+nbsp;+nbsp;+nbsp;- Fibre link definition
+nbsp;+nbsp;+nbsp;- Fibre testing steps
+nbsp;+nbsp;+nbsp;- Fibre inspection and cleaning
+nbsp;+nbsp;+nbsp;- Calibrating the test sets - 3 methods
+nbsp;+nbsp;+nbsp;- Setting up mandrel for testing
+nbsp;+nbsp;+nbsp;- Fibre loss budget calculation
+nbsp;+nbsp;+nbsp;- G.657 Bend insensitive fibre
+nbsp;+nbsp;+nbsp;- Optical Time-Domain Reflectometer (OTDR)